PICKOFF COIL SENSORS
The FC7
converts the pulsed output from your flowmeter into an analogue 4-20mA signal.
 Quick and easy to install Preset to your
requirements Monitor consumption and flow rates Improve your process Reduce
costs and waste 10 point linearisation Works with all pulsed flowmeters ISO
9001 certified manufacturer Weatherproof enclosure Outputs for
PLCs,computers etc. Highly accurate Monitor consumption and flow
rates High reliability Immunity to electrical noise Weatherproof
enclosure
Application
The FC7 will convert a pulsed flowmeter signal into a
loop powered 4-20 mA signal for instruments such as PLCs, computers, flow
controllers, chart recorders or local displays.
Installation The robust
aluminium enclosure allows the instrument to be installed almost anywhere. It
can be mounted in a panel, on to a wall or on to the flowmeter.
Instrument Function
The FC7 will accept pulsed signals from any flowmeter. It
provides you with an analogue output of 4 - 20 mA. It improves the accuracy by
correcting for the non linear performance of flowmeters.
Setup
The instrument is preset for your flowmeter using up to
10 linearisation points from the calibration certificate.
Specification
Construction: Protection: IP65 Materials: Aluminium with rubber
gasket Mounting: On to the flowmeter Or via screw holes in the base corners
Temp. range: 0 - 45 oC Power input: 12 -28 V d.c. loop powered Connections: PCB
mounted screw terminals via a weatherproof cable gland Input Signals: Frequency
range 0 to 3 kHz 1. Preamplifier: Sensitivity: low level <8mA high level
>11mA Input max: 3.0V 100mA 2. Proximity sensor: Namur DIN 19234
Sensitivity: low level <1mA high level >3mA 3. Pickoff coil: Input min:
10 mV RMS at 100Hz 45mV RMS at 3kHz Input max: 5V RMS 4. Switch closure:
Energising voltage: 5V Energising current: 10 mA DC 5. Voltage pulse:
Sensitivity: logic low <1V logic high >2.5V Input max: 40V
Output signals:
Output: Max. load: 4-20mA into 250 W @ 12 V dc or 4-20mA into 1K W
@ 28 V dc Response time: Approx. 400msec to 60% Linearity: 0.2 % of span D to A
converter: 15 bit Update time: 0.25 seconds
Outputs:
| Pulse: |
Two open collector transistors |
| |
Voltage max. 32 V dc load max. 1.0 A 600mW |
| |
Pulse duration 30 , 50 or 100 in msec (selectable) Other
pulse duration's are available |
| Analogue: |
0-1 mA into 5K or 0-5 mA into 1K |
| Linearity: |
+/- 0.5% of reading |
| Optional display |
1) 6 digit LCD counter. The reset button can be inhibited so
that long term usage can be monitored. Approx. 4 year battery life |
| |
2) 96 x 96 mm analogue flow rate indicator. Can be scaled in
any flow units e.g. litre/min, Kg/hour |
To view the FC7 Frequency to Current Converter pdf data
sheet click here:
To see available data sheets and
manuals click here: Download
Area