MODEL 202 RATE TOTALISER
The Model 202
has an LCD display of flowrate and flow total. It takes the output from
flowmeters and can be used for local or remote indication.
 Quick and easy to
set up Preset to your requirements Displays rate, total &
accumulated total Optional 4-20mA output Optional high & low alarms
Highly accurate Improve product quality Mounts on the pipe, wall or
flowmeter Battery or DC powered Waterproof
enclosure
Application
The 202 Rate Totaliser is designed to display the flow
rate and total of your process liquid. You can use it for monitoring,
controlling, dispensing, blending or filling of any liqiud when used with
turbine, positive displacement and pelton wheel flowmeters. The battery powered
version is ideal for areas where a power supply is not
available.
Operation The flowrate
and the resettable total are displayed simultaneously. The 202 stores a non
resettable total to monitor long term consumption .
Installation and Setup
The rate and totals can be displayed in any engineering
units for example litres per minute and barrels. The setup is easy via the
front keypad and it can be preset for your requirements. The 202 can be
mounted directly on to your flowmeter, wall mounted or pipe mounted. Cables are
installed via waterproof cable glands.
Optional Features 1.
Analogue 4-2OmA output An optional two wire 4-2OmA output is available
for transmitting the flow rate to other instruments or control equipment. It is
scalable to your requirements and provides a fast response to changes in
flowrate. The operating power is drawn from the 4-2OmA loop so that the
batteries will last indefinitely. 2. High and low flow alarms
Two flow rate alarms are available for monitoring the flow. The output will
trigger when the flow rises above or falls below the high and low alarm levels.
This option requires a DC power supply. 3.
Linearisation: The accuracy of your system can be improved by programming
any flowmeter errors into the 202.
Construction
The instrument is housed in a polycarbonate enclosure
that is completely watertight
Specification
| Display: |
LCD which is continuously powered |
| Resettable total: |
7 digits 10mm high resettable from the front
panel |
| Accumulated total: |
Displayed when the ACCUMTOT (Non resettable)
button is pressed |
| Rate: |
4 digits 8.5 mm high |
| K-factor: |
The pulses per unit of measurement ( eg
pulses/litre) is programmable in the range 0.2 to 29,999 |
| Decimal points: |
Decimal point positions are selectable for both rate and
total |
| Timebase: |
Rate can be displayed in units per second minute, hour or
day |
| Frequency range: |
0 to 5 kHz |
| Signal type: |
Switch settable for sinewave (40mV peak to peak min), open
collector, reed switch or pulse. |
| Batteries: |
Two lithium battery packs |
| Battery life: |
Battery life is dependent on the percentage of time that the
instrument is totalising flow. |
| 4-20mA Option: |
The 4mA and 20mA points are selectable |
| Accuracy: |
0.5% of range |
| Connection: |
Two wire |
| Voltage Drop: |
14 V maximum DC Power / |
| High and Low Flow Alarms Outputs: |
Two open collector outputs are available for high and low
flow alarms. The alarm points are programmable. |
| Switching power: |
200mA. 30V DC |
| Max DC power input: |
12-28 Volt maximum |
| Physical Temperature: |
-20oC to 70oC |
Input signals:
| 1. Pick-off Coil: |
Sine wave min: 7mV all frequencies |
|
Sine wave max: 35V high frequency 15V low
frequency |
| 2. Preamplifier: |
Switch levels: |
|
Low level < 8mA, high level > 12mA |
|
Input current max: 50mA |
| 3. Switch: |
Low frequency: dc to 400 Hz |
|
High frequency: dc to 5 kHz |
| 4. Voltage Pulse: |
Switch threshold selectable 2.5V or 1.4V |
| 5. Proximity |
Switch threshold 2.2V |
| Namur DIN 19234 |
Switch levels: low < 1mA high > 3mA |
|
Sensor power supply: 8.2V dc 50mA |
Outputs:
| Mounting: |
Universal mounting bracket supplied for mounting on wall or
panel. |
| Mounting options |
1.Pipe mounting kit to fix available: the unit on to a
pipe. |
|
2. Adaptor for mounting the instrument on to flowmeters. |
| Protection: |
Sealed to IP67 Cable entry: By cable glands. |
To view the 202 Rate Totaliser pdf data sheet click here: