Apollo manufacturer of flowmeters, sight glasses and instrumentation for liquids and fluids in water chemical, pharmaceutical and food processing industries. Turbine flowmeter, electromagnetic flow meters, positive displacement and ultrasonic flowmeters, rate totalisers, batch controllers, which accurate batch preset volume mass of liquid.
Apollo manufacturer of flowmeters, sight glasses and instrumentation for liquids and fluids in water chemical, pharmaceutical and food processing industries. Turbine flowmeter, electromagnetic flow meters, positive displacement and ultrasonic flowmeters, rate totalisers, batch controllers, which accurate batch preset volume mass of liquid.
Flowmeters
 Turbine
 Hygienic
 Electromagnetic
 Hoverflo
 Lowflo/Peltflo
 Variable Area
 Oval Gear
 Positive Displacement
 Mass
 Mechanical Water Meter
 Ultrasonic
 Vortex
Instruments
Sight Glasses
Downloads
Reference
Site Map
Contacts
Home


Apollo Flow Measurement Ltd
Charles Street
Walsall
WS2 9LZ


Tel 01922 645647
Tel 0800 3286674
Tel +44 1922 645647
sales@apolloflow.co.uk

 

ELECTROMAGNETIC FLOWMETER

The Toshiba LF410 electromagnetic flowmeter accurately measures the flow of almost any conducting liquids including foods, pharmaceuticals, pulps and slurries with suspended solids.

RN Turbine Flowmeter
Cost effective
Wide range
High accuracy
No obstruction to flow
Highly resistant ceramic lining
Easy to set up
Good stability and noise suppression

 

Application
Electromagnetic flowmeters are ideally suited for most conducting liquids including aggressive, abrasive and corrosive liquids and those containing solids. The bore of the flowmeter is smooth with no obstruction to flow hence the pressure drop is low. The measurement is independent of pressure, temperature, density, conductivity (above certain limits) and viscosity. Typical applications are for the measurement of chemicals, pharmaceuticals, pulp, foods, acids, alkalis, dyes, waste water and liquids containing solid matter.

Principle of Operation
The flowmeter consists of two parts: a detector which is mounted in the pipeline and through which the measured liquid flows, and a converter which may be mounted either integral with the detector or separately. The converter conditions and outputs the electrical signal from the detector. The measuring principle is based on Faradays Law of Electromagnetic Induction which states that if an electrical conductor, in this case the measured liquid, passes through a magnetic field a small electromotive force (EMF) is induced perpendicular to the field and flow. This EMF is proportional to the average flow velocity and is detected by two electrodes mounted in the wall of the detector and then fed to the converter. The divided multi sampling and noise suppression provides superior accuracy and stability. Presence of deposits on the electrodes have no effect on the zero point as long as some part of the electrode is exposed. The coil arrangement of the flowmeter is such that uneven flow can be measured correctly. The functional magnetic field distribution technique and the reduced number of components result in improved flow measurement efficiency and reliability.

Construction
The stainless steel construction is durable and gives excellent corrosion resistance. The rotor is machined from solid making it virtually indestructible. The sleeve bearings provide you with highly reliable performance over long periods.

Calibration
The flowmeter can be set to any flow range between the minimum and maximum flow ranges in the following table. A test certificate is issued for each flowmeter and the amplifier output is set to customer requirements.

Installation
The flowmeter can be mounted in any plane but should be maintained full of liquid at all times. For vertical installations flow should be upwards and in all cases the electrodes should be horizontal. This flowmeter has a short inlet-to-outlet length and should be installed with between five and ten pipe diameters upstream. No downstream diameters are required. The LF410/LF400 is a combined detector and converter. The LF410 can be mounted separate to the LF420 converter for remote mounting.

 Flow Ranges

Size mm
Minimum flow range (0-0.3 m/s) litres/min
Maximum flow range (0-10m/s) litres/min
15
0-3
0-100
25
0-9
0-300
40
0-23
0-750
50
0-35
0-1200
80
0-90
0-3000
100
0-140
0-5000
150
0-320
0-10000
200
0-560
0-20000
250
0-880
0-30000
300
0-1300
0-40000
350
0-1700
0-58000
400
0-2300
0-75000

 Detector Specification

Size: 15 to 400 mm diameter
Flow velocity: Lowest range 0 to 0.3 m/s Highest range 0 to 10 m/s
Fluid pressure: -1 bar up to the flange rating
Fluid temperature:
-10 to 80 oC for EPDM lined -10 to 120oC PTFE or ceramic lined
-10 to 180oC for ceramic lined and separate converter
Accuracy: See the table below
Conductivity: Minimum 5 microS/cm required
Connections: Wafer 15 - 200 mm
Flanges for 15 - 400 mm
Hygienic 25 - 100 mm
Flange Specs: ANSI 150,300 ND16,40

 Converter Specification

Display: 2 line 16 character dot matrix backlit LCD display
Current output: 4-20mA (max load 1 k W)
Digital output DO1: Transistor open collector
Capacity: Maximum 30V dc 200mA
Digital output DO2: Solid state relay
Capacity: Max 50V dc 150 mA
Pulse output: (DO1 only) 3.6-3600000 pulses/hour. Pulse width of 0.5 - 100 ms
DO1 or DO2 can be
used for the following:
Flow alarm output: High and low limit alarm
Empty pipe output: Alarm output for empty pipe
Preset point output: Output signal for when a preset quantity has been reached
Digital input: 20 - 30 V dc signal
Digital input can be set for: Multi range: 4-range switching to increase accuracy
Totaliser control: Start, stop and reset totaliser
Communications: A digital signal conforming to the HART protocol is superimposed on the 4-20mA signal
Protection: IP67 (NEMA4)
Temp range: -10 to +60 oC

Intrinsically Safe Version
The flowmeter can be mounted in the hazardous area.It is approved to FM Class 1 Division 1

 Power Supply

Mains: 100 to 240 V ac 50/60 Hz
DC: 24 V dc (allowable 20.4 -28.8V)
Surge protection: Surge protectors are installed in the power supply and current signal output circuits.
Power consumption: Approx. 10W

 Materials of Construction

Converter case: Aluminium alloy
Coating: Pearl-grey acrylic resin
Cable connection: 11-13mm cable gland
To view the Electromagnetic Flowmeter pdf data sheet click here:

To see available data sheets and manuals click here: Download Area

Click below to switch to the following flowmeters:
RN Turbine| Hygienic Turbine |Electromagnetic | Hoverflo | Lowflo/Peltflo | Variable Area | Oval Gear PD | Positive Displacement | Mass | Water Meter | Ultrasonic | Vortex